Ground Stationary EZ-Test Plans Template

Licensed Ground Stationary EZ-Test Plan Templates

Ground Stationary EZ-Test Plans Templates are licensed for a one year period and are renewable.  Each environmental test plan is compliant with MIL-STD-810 Task 405. EMI/EMC test plans are compliant with MIL-STD-461 per DI-EMCS-80201-B.

The Importance of Proper Documentation for Test and Evaluation and Ground Stationary EZ-Test Plans.

Each Ground Stationary EZ-Test Plans Template package includes one or more procedures which are commonly applied to ground stationary applications. We also have taken into consideration options for both operational and storage types of environmental testing procedures in each plan and the requisite parameters.

Test Plans Template Packet Contents

Environmental Test plan packets include:

  • Test Plan Template (protected PDF).  This document, pert the requirements of MIL-STD-810 provides procedures applicable to aircraft military applications. 
  • Test Plan Addendum (Word document).  This document is to be completed by the customer to document Unit Under Test (UUT) specific data.  This data includes modes of operation, pass/fail criteria, and functional and operational tests to be performed during the procedure as required by MIL-STD-810.
  • Test Lab Form (PDF Form).  This form communicates to lab the procedure to be performed, tailored test parameters, and test report requirements specified by MIL-STD-810.
  • Test Data Form (PDF Form).  This document allows for entry of all pretest, during test, and post test information as required by MIL-STD-810.
  • Test Label (Word document).  The label provides identification of photographs to be taken during the test process.

EMI/EMC and Electrical plan packets include:

  • Test Plan Template (protected PDF).  This document provides essential information detailing Equipment Under Test (EUT) set up, execution of test procedure, pass/fail criteria, and tolerances.  These test plans are written per the requirements of DI-EMCS-80201.
  • Test Plan Addendum (Word document).   This document is to be completed by the customer to include Equipment Under Test (EUT) specific information as required by DI-EMCS-80201.  This information includes Modes of Operation, Performance Checks, and Monitoring Equipment description.
  • Test Lab Form (PDF Form).  This form communicates to lab the procedure to be performed, test level parameters, and test report requirements specified by DI-EMCS-80201.
  • Test Label (Word document).  The label provides identification of photographs to be taken during the test process.
  • Tests to be Performed (PDF Form).  This form communicates all other methods of test to be performed by the test facility per requirements of MIL-STD-461.
  • Method Specific Forms (PDF Form).  These forms provide a means of data collection for the test witness as required for specific test methods.  These include forms for susceptibility and electrostatic discharge testing. 

EZ Test Plans are a proven solution.

Our Aircraft Military EZ-test plans are recognized by A2LA Certified Test Labs as reliable and comprehensive. We have included, in addition to guidance from the standards, additions including best practices which we have learned in test program management of equipment designed to Department of Defense standards.

CVG Strategy

CVG Strategy has extensive experience in test and evaluation for commercial, automotive, aerospace, defense, HALT, and HASS testing.  If you don’t find the exact test plan you are looking for we can provide custom documentation.

MIL-STD-810H

Method

Procedure Description

Buy Now

Method

500.6

Procedure Description

I Storage/Air Carriage, II Air Delivery, III Rapid Decompression

Buy Now

MIL-STD-810H

Method

501.7

Procedure Description

I Storage, II Operation

Buy Now

MIL-STD-810H

Method

502.7

Procedure Description

I Storage, II Operation

Buy Now

MIL-STD-810H

Method

503.7

Procedure Description

I-B Air Delivery, I-B Ground Transfer, I-C Multi-cycle shocks

Buy Now

Method

504.3

Procedure Description

Occasional, Intermittent, Extended

Buy Now

Method

505.7

Procedure Description

I Cycling, II Steady State

Buy Now

MIL-STD-810H

Method

506.6

Procedure Description

I Rain and Blowing Rain

Buy Now

MIL-STD-810H

Method

507.6

Procedure Description

I Induced, I Diurnal Cycles, II Aggravated

Buy Now

MIL-STD-810H

Method

508.8

Procedure Description

US and European Species

Buy Now

MIL-STD-810H

Method

509.7

Procedure Description

104 hours of alternating 24 wet and 24 dry

Buy Now

MIL-STD-810H

Method

510.7

Procedure Description

I Blowing Dust, II Blowing Sand

Buy Now

MIL-STD-810H

Method

512.6

Procedure Description

II Water Immersion Shallow Fording

Buy Now

MIL-STD-810H

Method

514.8

Procedure Description

I General Vibration Category 5 Loose Cargo, MIL-STD-202-201

Buy Now

MIL-STD-810H

Method

516.8

Procedure Description

II Transportation Shock and VI Bench Handling

Buy Now

MIL-STD-810H

Method

517.3

Procedure Description

III Mid Field; IV Far Field Mechanical; VI Far Field Electrodynamic

Buy Now

MIL-STD-810H

Method

521.4

Procedure Description

I Glazed Ice Accretion

Buy Now

MIL-STD-810H

Method

524.1

Procedure Description

I Diurnal Cycling Effects

Buy Now

MIL-STD-810H

Method

526.2

Procedure Description

Rail Crash 4 Impacts per Axis

Buy Now

MIL-STD-810G-1

MIL-STD-810G-1

Method

Procedure Description

Buy Now

MIL-STD-810G-1

Method

500.6

Procedure Description

I Storage/Air Carriage, II Air Delivery, III Rapid Decompression

Buy Now

MIL-STD-810G-1

Method

501.6

Procedure Description

I Storage, II Operation

Buy Now

MIL-STD-810G-1

Method

502.6

Procedure Description

I Storage, II Operation

Buy Now

MIL-STD-810G-1

Method

503.6

Procedure Description

I-B Air Delivery, I-B Ground Transfer, I-C Multi-cycle shocks

Buy Now

MIL-STD-810G-1

Method

504.2

Procedure Description

Occasional, Intermittent, Extended

Buy Now

Method

505.6

Procedure Description

I Cycling, II Steady State

Buy Now

MIL-STD-810G-1

Method

506.6

Procedure Description

I Rain and Blowing Rain

Buy Now

MIL-STD-810G-1

Method

507.6

Procedure Description

I Induced, I Diurnal Cycles, II Aggravated

Buy Now

MIL-STD-810G-1

Method

508.7

Procedure Description

US and European Species

Buy Now

MIL-STD-810G-1

Method

509.7

Procedure Description

104 hours of alternating 24 wet and 24 dry

Buy Now

MIL-STD-810G-1

Method

510.6

Procedure Description

I Blowing Dust, II Blowing Sand

Buy Now

MIL-STD-810G-1

Method

512.6

Procedure Description

II Water Immersion Shallow Fording

Buy Now

MIL-STD-810G-1

Method

514.7

Procedure Description

I General Vibration Category 5 Loose Cargo, MIL-STD-202-201

Buy Now

MIL-STD-810G-1

Method

516.7

Procedure Description

II Transportation Shock and VI Bench Handling

Buy Now

MIL-STD-810G-1

Method

517.2

Procedure Description

IIII Mid Field, IV Far;Field Mechanical, VI Far Field Electrodynamic

Buy Now

MIL-STD-810G-1

Method

521.4

Procedure Description

I Glazed Ice Accretion

Buy Now

MIL-STD-810G-1

Method

524.1

Procedure Description

I Diurnal Cycling Effects

Buy Now

MIL-STD-810G-1

Method

526.1

Procedure Description

Rail Crash 4 Impacts per Axis

Buy Now

EMI/EMC and Electrical

MIL-STD-461G

MIL-STD-461G

Method

Procedure Description

Buy Now

MIL-STD-461G

Method

CE102

Procedure Description

Conducted Emissions; Power Leads, 10 kHz to 10 MHz

Buy Now

MIL-STD-461G

Method

CS101

Procedure Description

Conducted Susceptibility, Power Leads, 30 Hz to 250 kHz

Buy Now

MIL-STD-461G

Method

CS114

Procedure Description

Conducted Susceptibility, Bulk Cable Injection, All cables 10 kHz to 200 MHz

Buy Now

MIL-STD-461G

Method

CS115

Procedure Description

Conducted Susceptibility, Pulse Excitation, 30 Hz

Buy Now

MIL-STD-461G

Method

CS116

Procedure Description

Conducted Susceptibility, Dampened Sinusodials

Buy Now

MIL-STD-461G

Method

CS118

Procedure Description

Conducted Susceptibility, Electrostatic Discharge (ESD)

Buy Now

MIL-STD-461G

Method

RE102

Procedure Description

Radiated Emissions, 8 MHz to 18 GHz,

Buy Now

MIL-STD-461G

Method

RS103

Procedure Description

Radiated Suscptibility, EUT and interconnecting cables, 2 MHz to 40 GHz

Buy Now

ground stationary EZ-test plans

How Can We Help?

Take a look around our site and contact us for more information on how we can help you meet your challenges.

Latest News